Examples for Athena WFI DE communications
"""
import communication as com
import packet_config_ATHENA_DE as de
import tools.dataprocessing.athena_de_frame_proc as fputils
# set up socket and connect
decon = com.Connector('', 12345, msgdecoding='hex')
decon.connect()
# example commands
# test echo interface (0x20)
decon.send(b'\x20\xDE\xAD')
# HK interface 0x33
decon.send(de.HkCmdRead(0x1000)) # get PCM MODE register
decon.send(de.HkCmdWrite(0x1000, 0x0001)) # set PCM MODE register
# CMD interface 0x34
decon.send(de.CmdWrite(0x3C00, 0x0001)) # write sequencer register
decon.send(de.CmdWrite(0x3C00, 1), rx=False) # write sequencer register, but don't fetch cmd response from socket
decon.send(de.CmdRead(0x3C00)) # read sequencer register
# SCI interface 0x35
decon.send(de.SciCmd(100)) # set science data output rate
# dump cmd log (decon.log)
logfile = '/path/to/de_cmd.log'
decon.dump_log(logfile)
# automatically log to file
decon.setup_storage(logfile)
# run rx thread on socket, received data is put in recvd_data_buf queue
decon.start_receiver()
decon.receiver.recvd_data_buf
# optionally, add custom TM processing
# define packet parser and event frame processor
ppa = de.FpmPktParser(96) # SCI (0x35) packets have 96 bytes by default (plus the interface byte)
ppr = de.FpmProcessor()
decon.start_receiver(pkt_parser_func=ppa, procfunc=ppr)
# get the frames from the processed data list and view them
fv = fputils.FrameViewer(de.filter_frames(decon.proc_data, empty_frames=False))
fv.show(cmap='inferno', interpolation='none')
# custom TM processing function; must take bytestring as arg *data*, and timestamp kwarg *ts*
def msg_to_hex_string(data, ts=''):
try:
return '{}: {}\n'.format(ts, data.hex(' ', 1))
except Exception as err:
print(err)
return '# ERROR #\n'
# this logs the received data hex-formatted in outfile
decon.start_receiver(procfunc=msg_to_hex_string, outfile='/path/to/de_rx.log', ofmode='w')
# processed data is also collected in
decon.receiver.proc_data
0% Loading or .