@@ -66,3 +66,10 @@ Scripts and input data used by Aiko Voigt when cmorizing the TRACMIP data using
Example scripts showing how to access TRACMIP data from the Pangeo cloud, and how to use this to redo a
couple of figures from the 2016 JAMES introduction paper.
--------------------------------------------
**Known data errors**
- The surface sensible heat flux in LMDZ5A has the wrong sign (negative instead of positive as in the other models). This can be corrected for by multiplying hfss with -1.